Kennedy Space Center
PROBLEM: Severe concrete deterioration from combination of atmospheric chlorides and fuel emission
STRUCTURE: Rocker Panel Base,
Launch Pad 39A
PROBLEM:
The Rocker panel base of Launch Pad 39A was experiencing severe concrete deterioration from exposure to a combination of corrosive atmospheric chlorides and fuel emission potassium percolate producing hydrochloric acid effluent from the shuttles rocket combustion system. Surface deterioration combined with wearing and cracking was allowing water to leak though the panel base to a tunnel below. Also, advanced corrosion of the imbedded steel in the structure and chloride contamination was contributing to the demise of the structure.

ABOVE: An example of the corrosion that appears on metal elements at the launch pad.

ABOVE: Corrosive chemical runoff from the rocket launches caused major damage to concrete
SOLUTION:

LEFT: Corroded metal elements on the launch pad being repaired and treated to prevent further corrosion to the structure.
To arrest further deterioration and corrosion, Surtreat formulations were applied to improve the chemical and physical properties of the concrete. The formulations that were chosen for this project inhibit deterioration; improve durability and longevity of the structure by:
- Substantially reduces porosity
- Elevates and controls pH
- Reacts with concrete to purge and stabilize contaminants (chlorides)
- Increases compressive strength
- Increases hardness
- Increases surface adhesion
- Converts ferrous oxide (rust) into hard inert shell
- Re-passivates white steel to half further corrosion
- Resists attack and penetration by acids, effluents, salts, and other contaminants
Demolition and removal of spalled and delaminated concrete took place before the application. Once the area was cleaned, application of Surtreat TPS II and TPS IV commenced. A special formulation was also used in designated repair areas to convert the ferrous oxide (rust) into a hard inert shell. Once the first application was completed, repairs to the spalled areas were made and a final application of formulations was made to the newly placed repairs.
CONCLUSION:
After application of Surtreat products, testing was conducted to ensure the expected results were obtained. The specified results of the project were met and the project was completed on time. Below are the results of the testing, which includes the measurements and the percentage change for each test conducted.
Half Cell Positive Change of 43%
350mV to -200mV
Corrosion Current Change of 133%
90 micro amps to +30 micro amps
Polarization Resistance change of 55%
4281 ohm-cm2 to 6612 ohm-cm2
LEFT: Section of concrete that had the Surtreat TPS applied to the surface.

WANT TO SEE HOW WE ACHEIVED A HALF CELL POSITIVE CHANGE OF 43% AFTER AN APPLICATION OF SURTREAT®?
Use the form to the right to request a download of our full NASA case study. One of our solutions specialists will contact you to understand how our corrosion solutions can help you on your next project!
Have a Project in Mind?
SURTREAT® works across a wide variety of industries. Our products renew, restore, and repair even the toughest structural damage.
REQUEST MORE INFO
Looking for a specific report? Send us a message and we will be in touch to get the information you need to start your project.